Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Opt Express ; 30(12): 22233-22246, 2022 Jun 06.
Article in English | MEDLINE | ID: covidwho-2065093

ABSTRACT

We propose a measurement method for sensitive and label-free detections of virus-like particles (VLPs) using color images of nanoplasmonic sensing chips. The nanoplasmonic chip consists of 5×5 gold nanoslit arrays and the gold surface is modified with specific antibodies for spike protein. The resonant wavelength of the 430-nm-period gold nanoslit arrays underwater environment is about 570 nm which falls between the green and red bands of the color CCD. The captured VLPs by the specific antibodies shift the plasmonic resonance of the gold nanoslits. It results in an increased brightness of green pixels and decreased brightness of red pixels. The image contrast signals of (green - red) / (red + green) show good linearity with the surface particle density. The experimental tests show the image contrast method can detect 100-nm polystyrene particles with a surface density smaller than 2 particles/µm2. We demonstrate the application for direct detection of SARS-CoV-2 VLPs using a simple scanner platform. A detection limit smaller than 1 pg/mL with a detection time less than 30 minutes can be achieved.


Subject(s)
Biosensing Techniques , COVID-19 , Nanostructures , Antibodies , Biosensing Techniques/methods , Gold/chemistry , Humans , Nanostructures/chemistry , Polystyrenes , SARS-CoV-2 , Spike Glycoprotein, Coronavirus , Surface Plasmon Resonance/methods
2.
J Nanobiotechnology ; 20(1): 6, 2022 Jan 04.
Article in English | MEDLINE | ID: covidwho-1608546

ABSTRACT

BACKGROUND: Gold nanoparticles (AuNPs) have been widely used in local surface plasmon resonance (LSPR) immunoassays for biomolecule sensing, which is primarily based on two conventional methods: absorption spectra analysis and colorimetry. The low figure of merit (FoM) of the LSPR and high-concentration AuNP requirement restrict their limit of detection (LOD), which is approximately ng to µg mL-1 in antibody detection if there is no other signal or analyte amplification. Improvements in sensitivity have been slow in recent for a long time, and pushing the boundary of the current LOD is a great challenge of current LSPR immunoassays in biosensing. RESULTS: In this work, we developed spectral image contrast-based flow digital nanoplasmon-metry (Flow DiNM) to push the LOD boundary. Comparing the scattering image brightness of AuNPs in two neighboring wavelength bands near the LSPR peak, the peak shift signal is strongly amplified and quickly detected. Introducing digital analysis, the Flow DiNM provides an ultrahigh signal-to-noise ratio and has a lower sample volume requirement. Compared to the conventional analog LSPR immunoassay, Flow DiNM for anti-BSA detection in pure samples has an LOD as low as 1 pg mL-1 within only a 15-min detection time and 500 µL sample volume. Antibody assays against spike proteins of SARS-CoV-2 in artificial saliva that contained various proteins were also conducted to validate the detection of Flow DiNM in complicated samples. Flow DiNM shows significant discrimination in detection with an LOD of 10 pg mL-1 and a broad dynamic detection range of five orders of magnitude. CONCLUSION: Together with the quick readout time and simple operation, this work clearly demonstrated the high sensitivity and selectivity of the developed Flow DiNM in rapid antibody detection. Spectral image contrast and digital analysis further provide a new generation of LSPR immunoassay with AuNPs.


Subject(s)
COVID-19 Serological Testing/methods , COVID-19/diagnosis , SARS-CoV-2/isolation & purification , Surface Plasmon Resonance/methods , Antibodies, Viral/immunology , COVID-19/immunology , COVID-19 Serological Testing/instrumentation , Equipment Design , Gold/chemistry , Humans , Immunoassay/instrumentation , Immunoassay/methods , Metal Nanoparticles/chemistry , SARS-CoV-2/immunology , Saliva/virology , Spike Glycoprotein, Coronavirus/immunology , Surface Plasmon Resonance/instrumentation
3.
Sensors and Actuators B: Chemical ; : 131327, 2021.
Article in English | ScienceDirect | ID: covidwho-1586490

ABSTRACT

Epstein-Barr virus (EBV) positivity is one of the indexes for diagnosing nasopharyngeal carcinoma (NPC). Moreover, systemic inflammatory responses can easily be triggered in patients who are both EBV- and coronavirus disease 2019 (COVID-19)-positive. Development of rapid and highly sensitive EBV screening methods has become important. In this study, a nanofluidic preconcentrator integrated with a nanoslit Fano resonance biosensor was developed to detect latent membrane protein 1 (LMP1) for an EBV diagnosis. Through nanoimprinting and aluminum deposition, the low-cost nanoslit plasmonic sensing chip can be mass-produced. The nanoporous membrane was patterned on a sensing chip as an ion selective channel to concentrate LMP1 proteins. Anti-LMP1 immunoglobulin G was then modified to a sensing chip to immunosense LMP1. The Fano resonant spectrum of the capped nanoslit array produced a transmission peak followed by a dip. We recorded and analyzed the spectrum using four methods, including area, center of mass, peak value, and dip value methods. With preconcentration, a limit of detection (LOD) of 100pg/ml and a sensing range of 100pg/ml to 10µg/ml was achieved using the peak value.

4.
Biosens Bioelectron ; 195: 113672, 2022 Jan 01.
Article in English | MEDLINE | ID: covidwho-1439904

ABSTRACT

We present the first combination of a microfluidic polymerase chain reaction (PCR) with a gold nanoslit-based surface plasmon resonance (SPR) sensor for detecting the DNA sequence of latent membrane protein 1 (LMP1). The PCR microchannel was produced through a laser scribing technique, and the SPR nanoslit chip was manufactured via hot-embossing nanoimprinting lithography. Afterward, the LMP1 DNA probe was adsorbed onto the SPR chip of the integrated device through electrostatic interactions for further detection. The device can complete the analytical procedure in around 36 min, while the traditional machine requires 105 min to achieve similar signals under the same PCR thermal cycles. The calibration curve with serially diluted LMP1 DNA exhibited the accuracy (R2 > 0.99) and sensitivity (limit of detection: ∼10-11 g/mL) of the device. Moreover, extracted DNA from Epstein-Barr virus (EBV)-positive cells were directly detected through the integrated chip. In brief, this all-in-one chip can amplify gene fragments at the front-end and detect them at the back-end, decreasing the time required for the analysis without compromising accuracy or sensitivity. We believe this label-free, real-time, low-cost device has enormous potential for rapid detection of various viruses, such as EBV and COVID-19.


Subject(s)
Biosensing Techniques , COVID-19 , Epstein-Barr Virus Infections , Gold , Herpesvirus 4, Human/genetics , Humans , Microfluidics , Polymerase Chain Reaction , SARS-CoV-2 , Viral Matrix Proteins/genetics
5.
Analyst ; 146(18): 5584-5591, 2021 Sep 13.
Article in English | MEDLINE | ID: covidwho-1347943

ABSTRACT

COVID-19 has shown that a highly specific and rapid diagnostic system is a necessity. A spectral imaging-based surface plasmon resonance (SPRi) platform with an integrated microfluidic biosensor to detect oligonucleotide sequences has been proposed to be a promising alternative for infectious diseases due to its safe and straightforward use. Approaches to reduce the DNA probe loading onto gold nanoparticles with various types of polyethylene glycol (PEG) were explored. Here, we demonstrated the stability of functionalised gold nanoparticles with unmodified PEG whilst lowering the probe loading density. The system was evaluated by performing the detection of a mimicking COVID-19 target sequence, single point-mutation sequence and fully mismatch sequence. Highly specific binding of the mimicking COVID-19 target sequence was observed and analysed by the spectral imaging SPR approach. Our work has demonstrated the potential of a controlled probe density using unmodified PEG as an especially promising functionalisation strategy in SPR spectral imaging assays.


Subject(s)
COVID-19 , Metal Nanoparticles , Gold , Humans , Limit of Detection , SARS-CoV-2 , Surface Plasmon Resonance
SELECTION OF CITATIONS
SEARCH DETAIL